. Aspire 7736/7736Z/7336 Series Aspire 7540 Series Service Guide Service guide files and updates are available on the ACER/CSD web; for more information, please refer to PRINTED IN TAIWAN. Revision History Please refer to the table below for the updates made on Aspire 7736/7736Z/7336 and Aspire 7540 Series service guide. Date Chapter Updates. Copyright Copyright © 2009 by Acer Incorporated. All rights reserved.
![User manual pdf User manual pdf](/uploads/1/2/4/1/124175556/998055958.jpg)
No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of Acer Incorporated. Conventions The following conventions are used in this manual: SCREEN MESSAGES NOTE WARNING CAUTION IMPORTANT Denotes actual messages that appear on screen. Gives bits and pieces of additional information related to the current topic. Alerts you to any damage that might result from doing or not doing specific actions. DIFFERENT part number code to those given in the FRU list of this printed Service Guide.
You MUST use the list provided by your regional Acer office to order FRU parts for repair and service of customer machines. Acer Bio-Protection (only for certain models).17 Acer GridVista (dual-display compatible).18 Hardware Specifications and Configurations. BIOS Recovery by Crisis Disk.107 FRU (Field Replaceable Unit) List Aspire 7736/7736Z/7336 Series and Aspire 7540 Series Exploded Diagram.112 Model Definition and Configuration Aspire 7736/7736Z/7336 Series.
™ ™ Acer InviLink Nplify 802.11b/g/Draft-N. ™ Acer InviLink 802.11b/g. For Aspire 7540 Series AMD Better By Design Program, featuring:. AMD Turion™ II Ultra dual-core processor. ™ AMD Turion II dual-core processor.
™ AMD Athlon 64 II dual-core processor. 2.1+Enhanced Data Rate (EDR).
LAN: Gigabit Ethernet; Wake-on-LAN ready. Modem: 56K ITU V.92; Wake-on-Ring ready. I/O Ports Acer Bio-Protection fingerprint reader. (For Aspire 7736/7736Z/7336 Series). Multi-in-1 card reader (SD/MMC/MS/MS PRO/xD).
USB 2.0 port. ™. Modem (RJ-11) port. DC-in jack for AC adapter. Environment Temperature:. Operating: 5 °C to 35 °C.
Non-operating: -20 °C to 65 °C. Humidity (non-condensing):. Operating: 20% to 80%. Non-operating: 20% to 80%.
Dimension and weight. System Block Diagram For Aspire 7736/7736Z/7336 Series: Chapter 1. For Aspire 7540 Series: Chapter 1. Your Acer Notebook tour After knowing your computer features, let us show you around your new computer. Front View Icon Item Acer Crystal Eye webcam Display screen Power button Description Web camera for video communication.
Contaminacion auditiva en bogota pdf programs online. Sample Characterization shows the demographic characterization of the sample.
(only for certain models) Also called Liquid-Crystal Display (LCD), displays computer output (Configuration may vary by models). LAN communication. Enables/disables the Bluetooth function. Indicates the status of Bluetooth communication. How to save page in pdf format in chrome. (only for certain models) Launches Acer Backup Management for three-step data backup.
Indicates when the hard disk drive is active. Lights up when Num Lock is activated.
Left View Icon Item DC-in jack Ethernet (RJ-45) port External display (VGA) port HDMI HDMI port USB 2.0 port Line-in jack Microphone jack Headphones/ speaker/line-out jack with S/PDIF support Description Connects to an AC adapter. Connects to an Ethernet 10/100/1000-based network. Connects to a display device (e.g., external monitor, LCD projector). Right View Icon Item Optical drive Optical disk access indicator Optical drive eject button Emergency eject hole Modem (RJ-11) port USB 2.0 port Kensington lock slot Rear View Item Ventilation slots Chapter 1 2 3 4 Internal optical drive; accepts CDs or DVDs. Lights up when the optical drive is active.
Bottom View Icon Item Battery bay Batter Lock Battery release latch Memory compartment Hard disk bay Ventilation slots and cooling fan Enable the computer to stay cool, even after prolonged use. Indicators The computer has several easy-to-read status indicators. Icon Function Power Battery. Backup key Touchpad Basics (with fingerprint reader) The following items show you how to use the touchpad with Acer Bio-Protection fingerprint reader. Move your finger across the touchpad (2) to move the cursor. Press the left (1) and right (4) buttons located beneath the touchpad to perform selection and execution. Tap twice (at the same speed as double-clicking a mouse button); rest your finger on the touchpad on the second tap and drag the cursor.
Center button (3) Swipe up/down/left/right using Acer FingerNav 4- way control function (Manufacturing option). Main touchpad (1) Chapter 1. Using the Keyboard The keyboard has full-sized keys and an embedded numeric keypad, separate cursor, lock, Windows, function and special keys. Lock Keys and numeric keypad The keyboard has three lock keys which you can toggle on and off. Lock key Caps Lock When Caps Lock is on, all alphabetic characters typed are in uppercase. Windows Keys The keyboard has two keys that perform Windows-specific functions. Windows Pressed alone, this key has the same effect as clicking on the Windows Start button; it launches the Start menu.
User Guide
It can also be used with other keys to provide a variety of functions: key before pressing the other key in the hotkey combination. Windows Mobility Center also includes Acer-specific settings like sharing folders overview/sharing service on or off, Bluetooth Add Device (if applicable), and a shortcut to the Acer user guide, drivers and utilities. To launch Windows Mobility Center: Use the shortcut key All Programs and click on Acer GridVista.
![Samsung galaxy core prime user manual Samsung galaxy core prime user manual](https://img.yumpu.com/21682201/1/358x208/69-1385-honeywell-20-programmable-thermostat-download-.jpg)
Intel® Core™2 Duo T6500 PGA (2.1 GHz) Intel Celeron 900 PGA (2.2 GHz) Aspire 7736Z Series: Intel Pentium Dual-Core T4200 PGA (2.0 GHz) Aspire 7540 Series: AMD Turion II M520 2.3 GHz AMD Athlon II M320 2.1 GHz AMD Turion M620 2.5 GHz Aspire 7736/7736Z/7336 Series: Mobile Intel®. System Memory Item Memory module combinations Memory Combinations Slot 1 1024MB 1024MB 1024MB 2048MB 2048MB 2048MB 4096MB NOTE: Above table lists some system memory configurations. You may combine DIMMs with various capacities to form other combinations. On above table, the configuration of slot 1 and slot 2 could be reversed. 1x1 BG (HM) Aspire 7336 series: QMI Wireless LAN Atheros HB93 1x2 BGN (HM) EM306 Aspire 7540 Series: QMI Wireless LAN Atheros HB93 1x2 BGN (HM) EM306; Foxconn Wirelss LAN Atheros HB95 1x1 BG (HM) 1154 Mbps, up to 270 Mbps for Draft-N 802.11b+g, Draft-N.
. Operation Guide 3M-50 To turn your 3M-50 ON, press the MODE button on the right side. This cycles the 3M-50 through HEAT, COOL, AUTO and OFF modes. The 3M-50 programmable communicating top cover Reset thermostat operates via a high-quality, easy-to- button use touch screen. HOME Screen Control Screens Before you operate the 3M-50 please get familiar with these basic control screens.
All the 3M-50 functions are accessed through these screens: HOME, MENU, PROGRAM and MANUAL. The 3M- 50 touch screen technology allows you to select (by touching) an item and change it using the +/- arrows or the time arrows. MENU Screen The MENU screen is the gateway to many functions or settings of the 3M-50. It is displayed when you press the MENU button. See page 10 for details Set Time Chirp set Filter Timer set Touch this area to set. PROGRAM Screen The PROGRAM screen sets the 3M-50 control for your home HVAC system. Press and hold PROG for 10 sec to access it.
After that it is displayed when you press the PROG button. See page 8 for details. MANUAL Screen The Manual Screen control screen is where you can make temporary changes to your 3M-50’s operation. From the Full HOME screen, touch the main temperature display to use this screen. See page 13 for details Manual Override Indicator. Make this simple HOME screen the default for your 3M-50, switch the mode to OFF and hold the PROG button for 12 seconds.
This Simple HOME screen gives you limited access to the 3M-50’s features, only the target temp can be changed. Initial Settings Press MENU to access the following commands (from HOME screen). Set day of the week Touch the Day of the week area to cycle through the days of the week to select the current day.
Set time of day Touch the Time of Day arrows to move the time selection forward or backward until it displays the current time. All Days TO CHANGE THE PROGRAM: Make sure the 3M-50 mode is set to either HEAT or COOL, then press the PROGRAM button. This puts you at the PROGRAM screen see page 4. The programmed start time is displayed in the upper left. PROGRAM cont.
Select the day you want to program. The day of the week starts at SU - Sunday and can be advanced to the day you want to program. Touch the day of the week area to cycle through the days of the week to the desired day. Select the time slot (period) you want to program (MORN, DAY, EVEN, NITE). (HVAC cycling rate) This feature allows you to set the desired variance in temperature between the 3M-50 setting and the room temperature required before the heating or cooling system will turn on—from 0.5° to 2.0° F (.25° to 1° C). For example, if SWING is set to 2.0° F and the 3M- 50 is set to 70°F Target Temperature, the heat cycle will start when room temperature drops to 68°F.
Set - Touch this to change the temperature display scale from o F to o C. FILTER - AIR FILTER ALERT - The 3M-50 can be programmed to remind you when the HVAC sytem’s air filter needs changing. Touch FILTER.
The display will show the usage to date. To UNLOCK, Press MENU. Touch and hold icon for 5 seconds for 2 bars (if not there already). Then touch and hold the icon for another 5 seconds. Each 5 second touch and hold must be separate. Touch to return to the Home screen. CALIBRATE Your thermostat was accurately calibrated at the factory to ±1°.
Recommend 2°F for very cold climates and the 4°F for warm climates. MANUAL Screen Functions The 3M-50 has 4 manual override commands. The manual screen is accessed by touching the large current temperature display in the middle of the HOME screen.
MORN, DAY and EVEN) and a different target for NITE. EMER (in HEAT PUMP type) If you set your 3M-50 for HEAT PUMP with auxiliary heat, EMER function is available on the MANUAL screen. If you touch EMER, it displays EMER ON. Your HEAT PUMP is disabled and auxiliary heat is your sole source of heat. The mode button sets the 3M-50 to HEAT, COOL, AUTO, or OFF modes. Press it once to step to the next mode.
Hp Envy 7640 User Manual
If the 3M-50 is in OFF and you want to return to the mode you were previously in, touch the OFF indicator on screen. RESET button The RESET button re-boots the 3M-50 processor. It does not effect the user programs that have been stored in permanent memory. Compressor Protection The 3M-50 has a minimum cycle time of 4 minutes to protect your compressor in cool and in heat pump (if you have one). The Home screen will show a small clock and A/C during this time and the compressor will not come on until the 4 minute delay is over.